Follow
Ken Yoshida
Title
Cited by
Cited by
Year
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
T Boretius, J Badia, A Pascual-Font, M Schuettler, X Navarro, K Yoshida, ...
Biosensors and Bioelectronics 26 (1), 62-69, 2010
4372010
Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes
N Lago, K Yoshida, KP Koch, X Navarro
IEEE Transactions on Biomedical Engineering 54 (2), 281-290, 2007
2422007
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
K Yoshida, K Horch
IEEE transactions on biomedical engineering 40 (5), 492-494, 1993
2401993
A 32-site neural recording probe fabricated by DRIE of SOI substrates
P Norlin, M Kindlundh, A Mouroux, K Yoshida, UG Hofmann
Journal of Micromechanics and Microengineering 12 (4), 414, 2002
2262002
Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
K Yoshida, K Horch
IEEE Transactions on Biomedical Engineering 43 (2), 167-176, 1996
1691996
Identification, localization, and modulation of neural networks for walking in the mudpuppy (Necturus maculatus) spinal cord
J Cheng, RB Stein, K Jovanovic, K Yoshida, DJ Bennett, Y Han
Journal of Neuroscience 18 (11), 4295-4304, 1998
1471998
On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees
S Micera, X Navarro, J Carpaneto, L Citi, O Tonet, PM Rossini, ...
IEEE Transactions on Neural Systems and Rehabilitation Engineering 16 (5 …, 2008
1462008
On the use of wavelet denoising and spike sorting techniques to process electroneurographic signals recorded using intraneural electrodes
L Citi, J Carpaneto, K Yoshida, KP Hoffmann, KP Koch, P Dario, S Micera
Journal of neuroscience methods 172 (2), 294-302, 2008
1292008
In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex
W Jensen, K Yoshida, UG Hofmann
IEEE Transactions on Biomedical Engineering 53 (5), 934-940, 2006
1242006
Decoding information from neural signals recorded using intraneural electrodes: toward the development of a neurocontrolled hand prosthesis
S Micera, L Citi, J Rigosa, J Carpaneto, S Raspopovic, G Di Pino, ...
Proceedings of the IEEE 98 (3), 407-417, 2010
1162010
Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces
S Micera, PM Rossini, J Rigosa, L Citi, J Carpaneto, S Raspopovic, ...
Journal of neuroengineering and rehabilitation 8 (1), 1-10, 2011
1122011
Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes
K Yoshida, RB Stein
IEEE Transactions on Biomedical Engineering 46 (2), 226-234, 1999
931999
Reduced fatigue in electrically stimulated muscle using dual channel intrafascicular electrodes with interleaved stimulation
K Yoshida, K Horch
Annals of biomedical engineering 21 (6), 709-714, 1993
831993
Multichannel thin-film electrode for intramuscular electromyographic recordings
D Farina, K Yoshida, T Stieglitz, KP Koch
Journal of Applied Physiology 104 (3), 821-827, 2008
822008
Nanoscale topography reduces fibroblast growth, focal adhesion size and migration-related gene expression on platinum surfaces
CP Pennisi, A Dolatshahi-Pirouz, M Foss, J Chevallier, T Fink, V Zachar, ...
Colloids and Surfaces B: Biointerfaces 85 (2), 189-197, 2011
812011
Accurate and representative decoding of the neural drive to muscles in humans with multi‐channel intramuscular thin‐film electrodes
S Muceli, W Poppendieck, F Negro, K Yoshida, KP Hoffmann, JE Butler, ...
The Journal of physiology 593 (17), 3789-3804, 2015
802015
Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
M Tosato, K Yoshida, E Toft, V Nekrasas, JJ Struijk
Medical and Biological Engineering and Computing 44 (3), 161-169, 2006
802006
The effects of varying deposition current density on bending behaviour in PPy (DBS)-actuated bending beams
S Maw, E Smela, K Yoshida, P Sommer-Larsen, RB Stein
Sensors and Actuators A: Physical 89 (3), 175-184, 2001
782001
Relationship between grasping force and features of single-channel intramuscular EMG signals
EN Kamavuako, D Farina, K Yoshida, W Jensen
Journal of neuroscience methods 185 (1), 143-150, 2009
772009
Stimulation selectivity of the “thin-film longitudinal intrafascicular electrode”(tfLIFE) and the “transverse intrafascicular multi-channel electrode”(TIME) in the large nerve …
A Kundu, KR Harreby, K Yoshida, T Boretius, T Stieglitz, W Jensen
IEEE transactions on neural systems and rehabilitation engineering 22 (2 …, 2013
702013
The system can't perform the operation now. Try again later.
Articles 1–20